Low Voltage Electrical Systems
Direct On Line Solutions
Complete range of standard starters.
Isolator Stations.
Junction Boxes.
Soft Starter Solutions
Complete range of standard starters.
Variable Speed Drive Solutions
Complete range of standard starters.
Distribution Boards
SANS 10142.
Main & sub distribution boards.
From 380V to 690/1000V.
Up to 6200A.
Fixed pattern Motor Control Centre
Steelwork & Copperwork.
IEC 61439 Compliant.
IEC 61641 Compliant.
From 380V to 690/1000V.
Up to 4000A,65kA/1s, Int.Arc 65kA/300ms.
Up to IP54, Form 3b/4a.
Fully withdrawable Motor Control Centre
From 380V to 690V.
Up to 5000A Main busbar,1090A Vertical busbar.
Short time withstand (1s) 50/80kA - 480V.
Degree of protection IP42, Form 3b & 4b.
Electrical Reticulation
4Sight OT Automation has been extensively involved in large electrical reticulation projects both urban and rural environments
(involving both overhead and underground).
Low Voltage Electrical Services
Design.
Procurement.
Manufacturing.
Setup and Configuration of Network Architecture.
Factory Acceptance Testing.
Installation.
Handover with Certificate of Compliance
Low Voltage Electrical Components
Switchgear
Moulded Case Circuit Breakers
Rated currents from 16 to 1600 A.
Short circuit breaking capacity of up to 80 kA (380/415 V).
Moulds with fixed and adjustable thermal and magnetic units.
Miniature Circuit Breakers
Rated currents from 2 to 125 A tripping characteristic curves B and C.
MCB in 1, 2, 3 and 4 poles.
Short-circuit breaking capacity: 3/10 kA IEC 60809 (residential).
510 kA IEC 60947-2 (industrial).
Air Circuit Breakers
Rated currents up to 6 300A.
Short-circuit breaking capacity of up to 120 kA (380/415 V).
Standard trigger unit with LSIG protection.
Fixed and withdrawable versions.
Complete range of accessories.
Motor Protection Circuit Breakers
Starting and protection for motors up to 18.5 KW / 25 HP at 380/415 V.
Adjustable thermal release for overload protection up to 100 A.
Electronic Overload Protection
Smart relay.
Reliability and precision on monitoring, operation and protection of LV electronic motor.
Compact and modular concept.
Full motor protection and monitoring through current and voltage measurements.
Multiple operating modes including PLC functions.
Ultra Rapid Semi Conductor Fuse Protection
Designed and tested according to IEC 60269 for currents from 2 to 1 000 A.
AR classes, NH type: protection against short-circuits in semiconductors / electronic equipment up to 690 V ac.
Compact Contactors
Contractors and overload relays.
Complete line from 9 to 800 A.
Direct mounting of contractors to overload relays up to 105 A.
Large accessary range.
Soft Starters
CE Certified.
UL Certified.
IEC Compliant.
Any motor application from 3 A to 2160 A.
Variable Speed Drives
CE Certified.
UL Certified.
IEC Compliant.
0.55 to 5600 kW.
Surge Protection
Type 1 to Type 3.
IEC Compliant.
Devices for installation in residential, and industrial environments.
Chokes/Reactors
Single Phase Line Chokes.Single phase input reactors, used to reduce harmonics.
Three Phase Line Chokes.Three phase input reactors, used to reduce harmonics.
Motor Chokes.
Three phase output reactors, used with long or multiple motor cables.

.png)